MRCOOL mini split heat pumps
The ENERGY STAR data lists 80 certified pairings from MRCOOL in 10 series. SEER2 runs from 18.0 to 28.1; the highest is in the O series. 59 pairings are listed as cold climate.
Kept at 5°F is calculated by DIY Splits, not certified: the heat output at 5°F divided by the heat output at 47°F, both from the certified data.
A series
MRCOOL, A series: 4 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| A-09-HP-C-115C | A-09-HP-WMAH-115C | 9,000 | 21.5 | 12.5 | 9.0 | 6,000 | 60% | No | R-410A | MRCOOL |
| A-09-HP-C-115D-O | A-09-HP-WMAH-115D-O | 9,000 | 21.5 | 12.5 | 9.0 | 6,500 | 65% | No | R-454B | MRCOOL |
| A-09-HP-C-230D-O | A-09-HP-WMAH-230D-O | 9,000 | 21.2 | 12.6 | 9.1 | 7,000 | 70% | Yes | R-454B | MRCOOL |
| A-24-HP-C-230D-O | A-24-HP-WMAH-230D-O | 24,000 | 18.7 | 10.0 | 9.3 | 17,000 | 71% | Yes | R-454B | MRCOOL |
DIY series
MRCOOL, DIY series: 23 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| DIY-09-HP-C-115D25-O | DIY-09-HP-WMAH-115D25-O | 9,000 | 23.6 | 14.0 | 11.5 | 7,300 | 73% | Yes | R-454B | MRCOOL |
| DIY-12-HP-C-115D25-O | DIY-12-HP-WMAH-115D25-O | 12,000 | 23.5 | 12.5 | 10.2 | 8,400 | 70% | Yes | R-454B | MRCOOL |
| DIYHH-12-HP-C-230D25-O | DIY-12-HP-WMAH-230D25-O | 12,000 | 23.5 | 12.8 | 10.0 | 11,000 | 92% | Yes | R-454B | MRCOOL |
| DIY-12-HP-C-115C25 | DIY-12-HP-WMAH-115C25 | 12,000 | 22.5 | 12.5 | 9.0 | 6,400 | 53% | No | R-410A | MRCOOL |
| DIY-12-HP-C-115C | DIY-12-HP-WMAH-115C25 | 12,000 | 22.5 | 12.5 | 9.0 | 6,400 | 53% | No | R-410A | MRCOOL |
| DIYHH-12-HP-C-230D25-O | DIYCASSETTE12HP-230D25-O | 12,000 | 22.2 | 12.5 | 10.8 | 11,500 | 92% | Yes | R-454B | MRCOOL |
| DIYHH-18-HP-C-230D25-O | DIYCASSETTE18HP-230D25-O | 16,700 | 19.8 | 12.5 | 12.2 | 17,500 | 88% | Yes | R-454B | MRCOOL |
| DIY-18-HP-C-230C25 | DIYCASSETTE18HP-230C25 | 17,000 | 23.0 | 12.5 | 10.3 | 10,800 | 57% | No | R-410A | MRCOOL |
| DIY-MULTI3-18HP230D-O | not listed | 18,000 | 23.9 | 13.0 | 10.0 | 13,300 | 74% | Yes | R-454B | MRCOOL |
| DIY-18-HP-C-230C25 | DIY-18-HP-WMAH-230C25 | 18,000 | 22.7 | 12.6 | 9.8 | 11,700 | 65% | No | R-410A | MRCOOL |
| DIY-18-HP-C-230C | DIY-18-HP-WMAH-230C25 | 18,000 | 22.7 | 12.6 | 9.8 | 11,700 | 65% | No | R-410A | MRCOOL |
| DIY-18-HP-C-230D25-O | DIY-18-HP-WMAH-230D25-O | 18,000 | 22.5 | 13.7 | 11.5 | 12,800 | 71% | Yes | R-454B | MRCOOL |
| DIY-18-HP-C-230D25-O | DIYCASSETTE18HP-230D25-O | 18,000 | 21.4 | 12.5 | 11.5 | 13,100 | 73% | Yes | R-454B | MRCOOL |
| DIY-MULTI2-18HP230C | not listed | 18,000 | 21.2 | 12.5 | 9.6 | 14,000 | 74% | Yes | R-410A | MRCOOL |
| DIYHH-18-HP-C-230D25-O | DIY-18-HP-WMAH-230D25-O | 18,000 | 21.2 | 12.5 | 11.0 | 18,000 | 100% | Yes | R-454B | MRCOOL |
| DIY-24-HP-C-230C25 | DIY-24-HP-WMAH-230C25 | 23,000 | 20.5 | 12.5 | 9.2 | 15,500 | 62% | No | R-410A | MRCOOL |
| DIY-24-HP-C-230C | DIY-24-HP-WMAH-230C25 | 23,000 | 20.5 | 12.5 | 9.2 | 15,500 | 62% | No | R-410A | MRCOOL |
| DIY-24-HP-C-230D25-O | DIY-24-HP-WMAH-230D25-O | 24,000 | 22.7 | 12.7 | 9.5 | 16,100 | 67% | No | R-454B | MRCOOL |
| DIY-MULTI4-27HP230D-O | not listed | 26,000 | 23.0 | 12.0 | 9.0 | 18,200 | 70% | Yes | R-454B | MRCOOL |
| DIY-MULTI3-27HP230C | not listed | 27,000 | 22.0 | 12.0 | 9.5 | 19,000 | 70% | Yes | R-410A | MRCOOL |
| DIY-MULTI5-36HP230D-O | not listed | 34,000 | 23.0 | 12.0 | 9.9 | 25,200 | 70% | Yes | R-454B | MRCOOL |
| DIY-MULTI6-48HP230D-O | not listed | 43,000 | 21.8 | 12.0 | 10.0 | 37,000 | 77% | Yes | R-454B | MRCOOL |
| DIY-MULTI6-55HP230D-O | not listed | 47,000 | 20.0 | 12.0 | 10.5 | 46,000 | 84% | Yes | R-454B | MRCOOL |
DIYP series
MRCOOL, DIYP series: 4 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| DIYP-09-HP-C-115DE11-O | DIYP-09-HP-WMAH-115DE13-O | 9,000 | 23.6 | 14.0 | 11.5 | 7,300 | 73% | Yes | R-454B | MRCOOL |
| DIYP-12-HP-C-115DE11-O | DIYP-12-HP-WMAH-115DE13-O | 12,000 | 23.5 | 12.5 | 10.2 | 8,400 | 70% | Yes | R-454B | MRCOOL |
| DIYP-18-HP-C-230DE11-O | DIYP-18-HP-WMAH-230DE13-O | 18,000 | 22.5 | 13.7 | 11.5 | 12,800 | 71% | Yes | R-454B | MRCOOL |
| DIYP-24-HP-C-230DE11-O | DIYP-24-HP-WMAH-230DE13-O | 24,000 | 22.7 | 12.7 | 9.5 | 16,100 | 67% | No | R-454B | MRCOOL |
EZ series
MRCOOL, EZ series: 2 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| EZPRO-09-HP-C-11511DE-O | EZPRO-09-HP-WMAH-115DE-O | 9,000 | 20.2 | 11.3 | 9.2 | 6,200 | 62% | No | R-454B | MRCOOL |
| EZPRO-09-HP-C-11516D-O | EZPRO-09-HP-WMAH-115D-O | 9,000 | 20.2 | 11.3 | 9.2 | 6,200 | 62% | No | R-454B | MRCOOL |
EZPRO series
MRCOOL, EZPRO series: 1 pairing, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| EZPRO-09-HP-C-11516 | EZPRO-09-HP-WMAH-115 | 9,000 | 20.0 | 11.5 | 9.4 | 6,400 | 64% | No | R-410A | MRCOOL |
MULTI series
MRCOOL, MULTI series: 8 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| MULTI3-18HP230C-O | not listed | 18,000 | 25.1 | 14.0 | 9.8 | 13,500 | 71% | Yes | R-454B | MRCOOL |
| MULTI2-18HP230B | not listed | 18,000 | 22.9 | 13.9 | 10.5 | 12,600 | 66% | No | R-410A | MRCOOL |
| MULTI4-27HP230C-O | not listed | 27,000 | 25.0 | 13.0 | 9.5 | 19,000 | 70% | Yes | R-454B | MRCOOL |
| MULTI3-27HP230B | not listed | 28,000 | 24.6 | 12.7 | 9.5 | 19,000 | 68% | No | R-410A | MRCOOL |
| MULTI5-36HP230C-O | not listed | 36,000 | 24.0 | 12.0 | 9.5 | 26,000 | 70% | Yes | R-454B | MRCOOL |
| MULTI4-36HP230B | not listed | 36,000 | 23.9 | 11.7 | 9.5 | 25,200 | 68% | No | R-410A | MRCOOL |
| MULTI6-48HP230C-O | not listed | 47,000 | 24.0 | 12.5 | 10.3 | 36,000 | 75% | Yes | R-454B | MRCOOL |
| MULTI5-48HP230B | not listed | 48,000 | 23.4 | 12.5 | 8.7 | 33,000 | 69% | No | R-410A | MRCOOL |
O series
MRCOOL, O series: 12 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| O-HH-09-HP-C-230A | O-09-HP-WMAH-230B | 9,000 | 28.1 | 16.2 | 11.5 | 10,600 | 88% | Yes | R-410A | MRCOOL |
| O-HH-09-HP-C-230B | O-09-HP-WMAH-230B | 9,000 | 28.1 | 16.2 | 11.5 | 10,600 | 88% | Yes | R-410A | MRCOOL |
| O-ES-09-HP-C-230B | O-09-HP-WMAH-230B | 9,000 | 25.5 | 15.0 | 12.3 | 7,500 | 75% | Yes | R-410A | MRCOOL |
| O-HH-12-HP-C-230A | O-12-HP-WMAH-230B | 12,000 | 25.5 | 14.0 | 10.4 | 12,000 | 100% | Yes | R-410A | MRCOOL |
| O-HH-12-HP-C-230B | O-12-HP-WMAH-230B | 12,000 | 25.5 | 14.0 | 10.4 | 12,000 | 100% | Yes | R-410A | MRCOOL |
| O-ES-12-HP-C-230B | O-12-HP-WMAH-230B | 12,000 | 24.6 | 13.7 | 10.7 | 8,000 | 67% | No | R-410A | MRCOOL |
| O-HH-18-HP-C-230A | O-18-HP-WMAH-230B | 18,000 | 21.5 | 12.5 | 11.3 | 18,000 | 100% | Yes | R-410A | MRCOOL |
| O-HH-18-HP-C-230B | O-18-HP-WMAH-230B | 18,000 | 21.5 | 12.5 | 11.3 | 18,000 | 100% | Yes | R-410A | MRCOOL |
| O-ES-24-HP-C-230B | O-24-HP-WMAH-230B | 24,000 | 22.0 | 14.0 | 10.0 | 15,500 | 62% | No | R-410A | MRCOOL |
| O-HH-24-HP-C-230A | O-24-HP-WMAH-230B | 24,000 | 21.5 | 13.0 | 11.4 | 25,000 | 86% | Yes | R-410A | MRCOOL |
| O-HH-24-HP-C-230B | O-24-HP-WMAH-230B | 24,000 | 21.5 | 13.0 | 11.4 | 25,000 | 86% | Yes | R-410A | MRCOOL |
| O-ES-24-HP-C-230C-O1 | O-24-HP-WMAH-230C-O | 24,000 | 21.0 | 13.0 | 13.5 | 24,200 | 83% | Yes | R-454B | MRCOOL |
O-ES series
MRCOOL, O-ES series: 8 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| O-ES-09-HP-C-230C-O1 | O-09-HP-WMAH-230C-O | 9,000 | 27.4 | 15.4 | 12.5 | 11,500 | 96% | Yes | R-454B | MRCOOL |
| O-ES-09-HP-C-230C-O1 | CASSETTE09HP-230C-O | 9,000 | 22.6 | 14.0 | 12.1 | 11,000 | 110% | Yes | R-454B | MRCOOL |
| O-ES-09-HP-C-230C-O1 | DUCT-09HP-230B-O | 9,000 | 21.4 | 13.4 | 12.5 | 11,200 | 112% | Yes | R-454B | MRCOOL |
| O-ES-12-HP-C-230C-O1 | O-12-HP-WMAH-230C-O | 12,000 | 25.4 | 13.4 | 10.5 | 11,500 | 96% | Yes | R-454B | MRCOOL |
| O-ES-12-HP-C-230C-O1 | CASSETTE12HP-230C-O | 12,000 | 22.2 | 12.5 | 11.6 | 11,500 | 96% | Yes | R-454B | MRCOOL |
| O-ES-12-HP-C-230C-O1 | DUCT-12HP-230B-O | 12,000 | 20.0 | 12.0 | 10.0 | 11,800 | 94% | Yes | R-454B | MRCOOL |
| O-ES-18-HP-C-230B | O-18-HP-WMAH-230B | 18,000 | 23.5 | 12.5 | 10.8 | 11,300 | 59% | No | R-410A | MRCOOL |
| O-ES-18-HP-C-230C-O1 | O-18-HP-WMAH-230C-O | 18,000 | 21.4 | 12.5 | 11.0 | 18,000 | 100% | Yes | R-454B | MRCOOL |
O-HH series
MRCOOL, O-HH series: 12 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| O-HH-09-HP-C-230C-O | O-09-HP-WMAH-230C-O | 9,000 | 27.4 | 15.4 | 12.5 | 11,500 | 96% | Yes | R-454B | MRCOOL |
| O-HH-09-HP-C-230C-O | CASSETTE09HP-230C-O | 9,000 | 22.6 | 14.0 | 12.1 | 11,000 | 110% | Yes | R-454B | MRCOOL |
| O-HH-09-HP-C-230C-O | DUCT-09HP-230B-O | 9,000 | 21.4 | 13.4 | 12.5 | 11,200 | 112% | Yes | R-454B | MRCOOL |
| O-HH-12-HP-C-230C-O | O-12-HP-WMAH-230C-O | 12,000 | 25.4 | 13.4 | 10.5 | 11,500 | 96% | Yes | R-454B | MRCOOL |
| O-HH-12-HP-C-230C-O | CASSETTE12HP-230C-O | 12,000 | 22.2 | 12.5 | 11.6 | 11,500 | 96% | Yes | R-454B | MRCOOL |
| O-HH-12-HP-C-230C-O | DUCT-12HP-230B-O | 12,000 | 20.0 | 12.0 | 10.0 | 11,800 | 94% | Yes | R-454B | MRCOOL |
| O-HH-18-HP-C-230C-O | CASSETTE18HP-230C-O | 16,000 | 20.0 | 12.5 | 12.3 | 17,000 | 89% | Yes | R-454B | MRCOOL |
| O-HH-18-HP-C-230C-O | DUCT-18HP-230B-O | 17,000 | 18.0 | 12.0 | 10.5 | 18,000 | 95% | Yes | R-454B | MRCOOL |
| O-HH-18-HP-C-230C-O | O-18-HP-WMAH-230C-O | 18,000 | 21.4 | 12.5 | 11.0 | 18,000 | 100% | Yes | R-454B | MRCOOL |
| O-HH-24-HP-C-230C-O | CASSETTE24HP-230C-O | 23,400 | 20.7 | 12.0 | 11.6 | 23,800 | 95% | Yes | R-454B | MRCOOL |
| O-HH-24-HP-C-230C-O | O-24-HP-WMAH-230C-O | 24,000 | 21.0 | 13.0 | 13.5 | 24,200 | 83% | Yes | R-454B | MRCOOL |
| O-HH-24-HP-C-230C-O | DUCT-24HP-230B-O | 24,000 | 19.0 | 12.0 | 11.7 | 24,000 | 92% | Yes | R-454B | MRCOOL |
TruInverter series
MRCOOL, TruInverter series: 6 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| AEPL**MHV23S0931B1A | AEPL**AWM23E0931B1A | 9,000 | 23.0 | 12.0 | 9.5 | 8,000 | 89% | Yes | R-32 | MRCOOL |
| AEPL**MHV23S0932B1A | AEPL**AWM23E0932B1A | 9,000 | 23.0 | 12.0 | 10.0 | 8,000 | 89% | Yes | R-32 | MRCOOL |
| AEPL**MHV23S1231B1A | AEPL**AWM23E1231B1A | 12,000 | 24.0 | 13.0 | 10.0 | 10,000 | 83% | Yes | R-32 | MRCOOL |
| AEPL**MHV23S1232B1A | AEPL**AWM23E1232B1A | 12,000 | 24.0 | 13.0 | 10.0 | 10,000 | 83% | Yes | R-32 | MRCOOL |
| AEPL**MHV22S1831B1A | AEPL**AWM22E1831B1A | 18,000 | 24.0 | 12.0 | 10.0 | 15,000 | 83% | Yes | R-32 | MRCOOL |
| AEPL**MHV22S2431B1A | AEPL**AWM22E2431B1A | 23,000 | 23.0 | 12.0 | 10.0 | 17,500 | 73% | Yes | R-32 | MRCOOL |
Data: ENERGY STAR certified heat pumps, last checked November 23, 2026