Senville mini split heat pumps
The ENERGY STAR data lists 62 certified pairings from Senville in 4 series. SEER2 runs from 18.0 to 33.3; the highest is in the SENE series. 54 pairings are listed as cold climate.
Kept at 5°F is calculated by DIY Splits, not certified: the heat output at 5°F divided by the heat output at 47°F, both from the certified data.
SEN series
Senville, SEN series: 24 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| SENA/09HF/OQ | SENA/09HF/IQ | 9,000 | 28.1 | 16.2 | 11.5 | 10,600 | 88% | Yes | R-410A | Senville |
| SENL/09CD220/OY | SENL/09CD220/IY | 9,000 | 21.7 | 12.6 | 9.1 | 6,400 | 64% | No | R-410A | Senville |
| SENL/09CD/OY | SENL/09CD/IY | 9,000 | 21.5 | 12.5 | 9.0 | 6,000 | 60% | No | R-410A | Senville |
| SENA/09HF/OQ | SENA/09HF/ICZ | 9,000 | 20.5 | 13.0 | 10.3 | 10,000 | 102% | Yes | R-410A | Senville |
| SENA/09HF/OQ | SENA/09HF/ID | 9,000 | 20.2 | 13.2 | 12.0 | 10,800 | 108% | Yes | R-410A | Senville |
| SENA/12HF/OQ | SENA/12HF/IQ | 12,000 | 25.5 | 14.0 | 10.4 | 12,000 | 100% | Yes | R-410A | Senville |
| SENA/12HF/OQ | SENA-12HF-IFU | 12,000 | 24.2 | 13.3 | 10.7 | 11,900 | 99% | Yes | R-410A | Senville |
| SENA/12HF/OQ | SENA/12HF/IFQ | 12,000 | 23.6 | 13.0 | 10.0 | 12,000 | 100% | Yes | R-410A | Senville |
| SENA/12HF/OQ | SENA/12HF/ICZ | 12,000 | 22.3 | 12.7 | 10.2 | 11,300 | 94% | Yes | R-410A | Senville |
| SENA/12HF/OQ | SENA/12HF/ID | 12,000 | 19.5 | 11.7 | 10.0 | 12,100 | 97% | Yes | R-410A | Senville |
| SENA/18HF/OQ | SENA/18HF/ICZ | 16,000 | 20.0 | 12.5 | 9.5 | 16,000 | 94% | Yes | R-410A | Senville |
| SENA/18HF/OQ | SENA/18HF/IF | 17,000 | 20.5 | 12.5 | 9.8 | 16,800 | 93% | Yes | R-410A | Senville |
| SENA/18HF/OQ | SENA/18HF/ID | 17,000 | 18.0 | 11.7 | 9.5 | 17,700 | 93% | Yes | R-410A | Senville |
| SENA/18HF/MOQ | not listed | 18,000 | 22.9 | 13.9 | 10.5 | 12,600 | 66% | No | R-410A | Senville |
| SENA/18HF/OQ | SENA/18HF/IQ | 18,000 | 21.5 | 12.5 | 11.3 | 18,000 | 100% | Yes | R-410A | Senville |
| SENA/24HF/OQ | SENA/24HF/IQ | 24,000 | 21.5 | 13.0 | 11.4 | 25,000 | 86% | Yes | R-410A | Senville |
| SENA/24HF/OQ | SENA/24HF/ICQ | 24,000 | 20.5 | 11.0 | 11.5 | 25,800 | 103% | Yes | R-410A | Senville |
| SENA/24HF/OQ | SENA/24HF/IF | 24,000 | 20.5 | 11.7 | 11.0 | 25,000 | 100% | Yes | R-410A | Senville |
| SENA/24HF/OQ | SENA/24HF/ID | 24,000 | 19.2 | 12.0 | 10.5 | 27,000 | 108% | Yes | R-410A | Senville |
| SENA/30HF/MOQ | not listed | 28,000 | 24.6 | 12.7 | 9.5 | 19,000 | 68% | No | R-410A | Senville |
| SENL-30CD-OL | SENL-30CD-ILL | 30,000 | 20.0 | 11.0 | 9.2 | 19,700 | 66% | No | R-454B | Senville |
| SENA-33HF-OQ | SENA-33HF-IQ | 33,000 | 19.5 | 12.0 | 10.0 | 34,600 | 99% | Yes | R-410A | Senville |
| SENA/36HF/MOQ | not listed | 36,000 | 23.9 | 11.7 | 9.5 | 25,200 | 68% | No | R-410A | Senville |
| SENA/48HF/MOQ | not listed | 48,000 | 23.4 | 12.5 | 8.7 | 33,000 | 69% | No | R-410A | Senville |
SENA series
Senville, SENA series: 31 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| SENA-06HF-OG | SENA-06HF-IGG | 6,000 | 25.5 | 18.0 | 14.8 | 7,700 | 110% | Yes | R-454B | Senville |
| SENA-06HF-OG | SENA-06HF-1WCG | 6,500 | 22.0 | 15.0 | 12.0 | 8,100 | 109% | Yes | R-454B | Senville |
| SENA-09HF-OG | SENA-09HF-IGG | 9,000 | 27.4 | 15.4 | 12.5 | 11,500 | 96% | Yes | R-454B | Senville |
| SENA-09HF-OG | SENA-09HF-1WCG | 9,000 | 24.0 | 14.6 | 12.1 | 10,600 | 97% | Yes | R-454B | Senville |
| SENA-09HF-OG | SENA-09HF-ICG | 9,000 | 22.6 | 14.0 | 12.1 | 11,000 | 110% | Yes | R-454B | Senville |
| SENA-09HF-OG | SENA-09HF-IDG | 9,000 | 21.4 | 13.4 | 12.5 | 11,200 | 112% | Yes | R-454B | Senville |
| SENA-12HF-OG | SENA-12HF-IGG | 12,000 | 25.4 | 13.4 | 10.5 | 11,500 | 96% | Yes | R-454B | Senville |
| SENA-12HF-OG | SENA-12HF-IFG | 12,000 | 25.0 | 12.5 | 10.5 | 11,300 | 94% | Yes | R-454B | Senville |
| SENA-12HF-OG | SENA-12HF-1WCG | 12,000 | 23.0 | 13.0 | 10.0 | 11,500 | 92% | Yes | R-454B | Senville |
| SENA-12HF-OG | SENA-12HF-ICG | 12,000 | 22.2 | 12.5 | 11.6 | 11,500 | 96% | Yes | R-454B | Senville |
| SENA-12HF-OG | SENA-12HF-IDG | 12,000 | 20.0 | 12.0 | 10.0 | 11,800 | 94% | Yes | R-454B | Senville |
| SENA-15HF-OG | SENA-15HF-IGG | 15,000 | 23.5 | 11.7 | 9.9 | 11,500 | 77% | Yes | R-454B | Senville |
| SENA-18HF-OG | SENA-18HF-ICG | 16,000 | 20.0 | 12.5 | 12.3 | 17,000 | 89% | Yes | R-454B | Senville |
| SENA-18HF-OG | SENA-18HF-1WCG | 16,700 | 20.6 | 12.5 | 12.2 | 17,500 | 88% | Yes | R-454B | Senville |
| SENA-18HF-OG | SENA-18HF-IFG | 17,000 | 20.4 | 12.5 | 10.3 | 17,000 | 89% | Yes | R-454B | Senville |
| SENA-18HF-OG | SENA-18HF-IDG | 17,000 | 18.0 | 12.0 | 10.5 | 18,000 | 95% | Yes | R-454B | Senville |
| SENA-18HF-OG | SENA-18HF-IGG | 18,000 | 21.4 | 12.5 | 11.0 | 18,000 | 100% | Yes | R-454B | Senville |
| SENA-18HF-MOA | not listed | 19,000 | 25.0 | 15.0 | 10.4 | 19,000 | 95% | Yes | R-454B | Senville |
| SENA-18HF-MOB | not listed | 19,000 | 22.0 | 12.5 | 9.8 | 19,700 | 99% | Yes | R-410A | Senville |
| SENA-24HF-OG | SENA-24HF-IFG | 22,000 | 20.4 | 12.0 | 12.1 | 24,200 | 93% | Yes | R-454B | Senville |
| SENA-24HF-OG | SENA-24HF-ICG | 23,400 | 20.7 | 12.0 | 11.6 | 23,800 | 95% | Yes | R-454B | Senville |
| SENA-24HF-OG | SENA-24HF-IGG | 24,000 | 21.0 | 13.0 | 13.5 | 24,200 | 83% | Yes | R-454B | Senville |
| SENA-24HF-OG | SENA-24HF-IDG | 24,000 | 19.0 | 12.0 | 11.7 | 24,000 | 92% | Yes | R-454B | Senville |
| SENA-28HF-MOA | not listed | 27,000 | 23.0 | 12.5 | 10.5 | 27,000 | 100% | Yes | R-454B | Senville |
| SENA-28HF-MOB | not listed | 28,000 | 23.0 | 12.5 | 10.6 | 25,000 | 89% | Yes | R-410A | Senville |
| SENA-33HF-OG | SENA-33HF-IGG | 33,000 | 19.5 | 12.0 | 10.5 | 35,000 | 97% | Yes | R-454B | Senville |
| SENA-36HF-MOA | not listed | 36,000 | 23.0 | 13.0 | 10.7 | 36,000 | 100% | Yes | R-454B | Senville |
| SENA-36HF-MOB | not listed | 36,000 | 22.4 | 12.5 | 10.9 | 37,000 | 103% | Yes | R-410A | Senville |
| SENA-48HF-MOA | not listed | 47,000 | 23.0 | 12.0 | 11.0 | 47,000 | 96% | Yes | R-454B | Senville |
| SENA-48HF-MOB | not listed | 48,000 | 21.8 | 11.7 | 9.8 | 45,000 | 92% | Yes | R-410A | Senville |
| SENA-55HF-MOA | not listed | 53,000 | 20.0 | 11.7 | 10.7 | 48,000 | 87% | Yes | R-454B | Senville |
SENE series
Senville, SENE series: 4 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| SENE-09EL-OH | SENE-09EL-IHH | 9,000 | 33.3 | 17.0 | 14.6 | 13,500 | 113% | Yes | R-454B | Senville |
| SENE-12EL-OH | SENE-12EL-IHH | 12,000 | 29.4 | 14.2 | 12.7 | 13,500 | 113% | Yes | R-454B | Senville |
| SENE-18EL-OH | SENE-18EL-IHH | 18,000 | 25.6 | 15.0 | 16.2 | 22,600 | 113% | Yes | R-454B | Senville |
| SENE-24EL-OH | SENE-24EL-IHH | 24,000 | 25.0 | 14.0 | 11.0 | 20,000 | 83% | Yes | R-454B | Senville |
SENL series
Senville, SENL series: 3 pairings, sorted by cooling capacity, smallest first, then by SEER2, highest first.
| Outdoor unit | Indoor unit | Cooling BTU/h | SEER2 | EER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| SENL-09CD-OL | SENL-09CD-ILL | 9,000 | 21.5 | 12.5 | 9.0 | 6,500 | 65% | No | R-454B | Senville |
| SENL-09CD220-OL | SENL-09CD220-ILL | 9,000 | 21.2 | 12.6 | 9.1 | 7,000 | 70% | Yes | R-454B | Senville |
| SENL-24CD-OL | SENL-24CD-ILL | 24,000 | 18.7 | 10.0 | 9.3 | 17,000 | 71% | Yes | R-454B | Senville |
Data: ENERGY STAR certified heat pumps, last checked November 23, 2026