DIY Splits

How do the 12,000 BTU mini splits compare?

Updated November 22, 2026

The Senville SENE-12EL-OH with the SENE-12EL-IHH indoor unit has the highest SEER2 of the 12,000 BTU pairings, 29.4, as well as the highest HSPF2, 12.7, and the most heat at 5°F, 13,500 BTU/h. The Pioneer YN012GMSI24RPG with FB012GMSILDFHG has the highest COP at 5°F, 2.50, yet keeps 74% of its 47°F output there.

61 pairings, sorted by SEER2, highest first.

Outdoor unitBrandSeriesIndoor unitSEER2HSPF2Heat at 5°F BTU/hKept at 5°F % of 47°FCOP at 5°FCold climateRefrigerantSeller
SENE-12EL-OHSenvilleSENESENE-12EL-IHH29.412.713,500113%2.00YesR-454BSenville
O-HH-12-HP-C-230AMRCOOLOO-12-HP-WMAH-230B25.510.412,000100%1.80YesR-410AMRCOOL
O-HH-12-HP-C-230BMRCOOLOO-12-HP-WMAH-230B25.510.412,000100%1.80YesR-410AMRCOOL
SENA/12HF/OQSenvilleSENSENA/12HF/IQ25.510.412,000100%1.80YesR-410ASenville
O-ES-12-HP-C-230C-O1MRCOOLO-ESO-12-HP-WMAH-230C-O25.410.511,50096%1.80YesR-454BMRCOOL
O-HH-12-HP-C-230C-OMRCOOLO-HHO-12-HP-WMAH-230C-O25.410.511,50096%1.80YesR-454BMRCOOL
SENA-12HF-OGSenvilleSENASENA-12HF-IGG25.410.511,50096%1.80YesR-454BSenville
048-C-TPH-12K2V-25S-OUTDellaTPH048-C-TPH-12K2V-C-IN25.010.512,000100%1.80YesR-454BDella
048-TPH-12K2V-25S-OUTDellaTPH048-TPH-12K2V-25S-IN25.010.512,000100%1.80YesR-454BDella
048-TPH-12K2V-25S-OUTDellaTPH048-TPH-12K2V-C-IN25.010.512,000100%1.80YesR-454BDella
YN012GLSI25RPHPioneerDiamante HyperformanceWT012GLSI25HLH25.010.512,000100%1.80YesR-454BPioneer
SENA-12HF-OGSenvilleSENASENA-12HF-IFG25.010.511,30094%1.88YesR-454BSenville
O-ES-12-HP-C-230BMRCOOLOO-12-HP-WMAH-230B24.610.78,00067%2.39NoR-410AMRCOOL
YN012GMSI24RPGPioneerYNFB012GMSILDFHG24.611.08,90074%2.50YesR-454BPioneer
SENA/12HF/OQSenvilleSENSENA-12HF-IFU24.210.711,90099%1.99YesR-410ASenville
048-C-TP-12K2V-24S-OUTDellaTP048-C-TP-12K2V-C-IN24.010.09,10072%2.10YesR-454BDella
048-TP-12K2V-24S-OUTDellaTP048-TP-12K2V-24S-IN24.010.09,10072%2.10YesR-454BDella
048-TP-12K2V-24S-OUTDellaTP048-TP-12K2V-C-IN24.010.09,10072%2.10YesR-454BDella
AEPL**MHV23S1231B1AMRCOOLTruInverterAEPL**AWM23E1231B1A24.010.010,00083%1.80YesR-32MRCOOL
AEPL**MHV23S1232B1AMRCOOLTruInverterAEPL**AWM23E1232B1A24.010.010,00083%1.80YesR-32MRCOOL
YN012GLSI24RPGPioneerDiamante UltraWT012GLSI24HLG24.010.09,10072%2.10YesR-454BPioneer
YN012GLUI25RPQPioneerDiamante FreshWT012GLUI25FVQ24.09.510,10077%2.00YesR-32Pioneer
SENA/12HF/OQSenvilleSENSENA/12HF/IFQ23.610.012,000100%1.89YesR-410ASenville
DIY-12-HP-C-115D25-OMRCOOLDIYDIY-12-HP-WMAH-115D25-O23.510.28,40070%2.08YesR-454BMRCOOL
DIYHH-12-HP-C-230D25-OMRCOOLDIYDIY-12-HP-WMAH-230D25-O23.510.011,00092%1.80YesR-454BMRCOOL
DIYP-12-HP-C-115DE11-OMRCOOLDIYPDIYP-12-HP-WMAH-115DE13-O23.510.28,40070%2.08YesR-454BMRCOOL
YN012GHFI25RPHPioneerWYF HyperformanceWF012GHFI25HLH23.59.58,40070%2.05YesR-410APioneer
048-C-TP-12K1V-23S-OUTDellaTP048-C-TP-12K1V-C-IN23.010.08,90072%2.10YesR-454BDella
048-TP-12K1V-23S-OUTDellaTP048-TP-12K1V-23S-IN23.010.08,90072%2.10YesR-454BDella
048-TP-12K1V-23S-OUTDellaTP048-TP-12K1V-C-IN23.010.08,90072%2.10YesR-454BDella
048-TP-12K2V-23S-OUTDellaTP048-TP-12K2V-23S-IN23.09.59,10076%1.80YesR-410ADella
YN012ALSI24RPGPioneerDiamante UltraWT012ALSI24HLG23.010.08,90072%2.10YesR-454BPioneer
YN012GLFI22RPDPioneerDiamante UltraWT012GLFI22HLD23.09.59,10076%1.80YesR-410APioneer
SENA-12HF-OGSenvilleSENASENA-12HF-1WCG23.010.011,50092%2.00YesR-454BSenville
YN012AMFI22RPEPioneerYNWS012AMFI22HLE22.710.06,50054%2.00NoR-410APioneer
YN012GMFI20RPDPioneerYNCB012GMFILCFHD22.710.08,00067%2.27NoR-410APioneer
YN012GMFI22RPEPioneerYNCB012GMFILCFHD22.710.08,00067%2.27NoR-410APioneer
YN012GMFI22RPEPioneerYNFB012GMFILDFHE22.710.28,40070%2.26YesR-410APioneer
DIY-12-HP-C-115C25MRCOOLDIYDIY-12-HP-WMAH-115C2522.59.06,40053%1.96NoR-410AMRCOOL
DIY-12-HP-C-115CMRCOOLDIYDIY-12-HP-WMAH-115C2522.59.06,40053%1.96NoR-410AMRCOOL
SENA/12HF/OQSenvilleSENSENA/12HF/ICZ22.310.211,30094%1.89YesR-410ASenville
DIYHH-12-HP-C-230D25-OMRCOOLDIYDIYCASSETTE12HP-230D25-O22.210.811,50092%2.10YesR-454BMRCOOL
O-ES-12-HP-C-230C-O1MRCOOLO-ESCASSETTE12HP-230C-O22.211.611,50096%2.00YesR-454BMRCOOL
O-HH-12-HP-C-230C-OMRCOOLO-HHCASSETTE12HP-230C-O22.211.611,50096%2.00YesR-454BMRCOOL
SENA-12HF-OGSenvilleSENASENA-12HF-ICG22.211.611,50096%2.00YesR-454BSenville
YN012GMSI24RPGPioneerYNCK012GMSILDFHG22.110.08,60072%2.48YesR-454BPioneer
048-MS-12K1VR-22S-M-OUTDellaM048-MS-12K1VR-22S-M-IN22.09.59,20075%2.10YesR-32Della
048-MS-12K2VR-22S-M-OUTDellaM048-MS-12K2VR-22S-M-IN22.09.59,10074%2.00YesR-32Della
048-TP-12K1V-22S-OUTDellaTP048-TP-12K1V-22S-IN22.09.08,70073%1.80YesR-410ADella
YN012ALFI22RPDPioneerDiamante UltraWT012ALFI22HLD22.09.08,70073%1.80YesR-410APioneer
YN012GMFI22RPEPioneerYNCK012GMFILCFHD22.09.87,80062%2.21NoR-410APioneer
048-MS-12K2VR-21S-OUTDellaQ048-MS-12K2VR-21S-QC-IN21.010.08,20067%2.15NoR-32Della
048-TP-12K2V-24S-OUTDellaCC048-CC-12K2V-IN21.010.09,00075%1.90YesR-454BDella
YN012GLSI24RPGPioneerDiamante UltraCT012GLSILCFHG21.010.09,00075%1.90YesR-454BPioneer
O-ES-12-HP-C-230C-O1MRCOOLO-ESDUCT-12HP-230B-O20.010.011,80094%1.90YesR-454BMRCOOL
O-HH-12-HP-C-230C-OMRCOOLO-HHDUCT-12HP-230B-O20.010.011,80094%1.90YesR-454BMRCOOL
SENA-12HF-OGSenvilleSENASENA-12HF-IDG20.010.011,80094%1.90YesR-454BSenville
SENA/12HF/OQSenvilleSENSENA/12HF/ID19.510.012,10097%1.96YesR-410ASenville
048-TP-12K2V-24S-OUTDellaDCnot listed19.08.48,80073%1.80YesR-454BDella
YN012GLSI24RPGPioneerDiamante Ultranot listed19.08.48,80073%1.80YesR-454BPioneer
YN012GMFI22RPEPioneerYNRB012GMFILDFHD19.010.38,40070%2.26YesR-410APioneer

Kept at 5°F is calculated by DIY Splits, not certified: the heat output at 5°F divided by the heat output at 47°F, both from the certified data.

Efficiency in the cold is not heat in the cold

COP at 5°F is the heating rate divided by the electrical power used. The Pioneer pairing that leads on it puts out 8,900 BTU/h at 5°F; the Senville SENE-12EL-OH puts out more heat there at a lower COP.

One series name, a wide range

The share of heat kept at 5°F varies widely inside MRCOOL’s DIY series at this size. The DIY-12-HP-C-115C25 and DIY-12-HP-C-115C, each with DIY-12-HP-WMAH-115C25, put out 6,400 BTU/h at 5°F, 53% of their 47°F output, the lowest share of any 12,000 BTU pairing. They use R-410A and are not listed as cold climate. The DIYHH-12-HP-C-230D25-O with DIY-12-HP-WMAH-230D25-O puts out 11,000 BTU/h at 5°F, 92%, uses R-454B and is listed as cold climate. The series name does not tell these apart; the full model numbers do.

Three refrigerants

Pairings at this size use R-454B, R-410A and R-32. The refrigerant page sets R-410A and R-454B pairings from the same series side by side at this size, with the R-32 pairings.

Sources

  1. ENERGY STAR defines COP as the heating rate divided by the electrical power used. www.energystar.gov

Related

Data: ENERGY STAR certified heat pumps, last checked November 23, 2026