No 24,000 BTU pairing leads on both cooling and heating. The Senville SENE-24EL-OH with SENE-24EL-IHH has the highest SEER2, 25.0, but puts out 20,000 BTU/h at 5°F, 83% of its 47°F output. The most heat at 5°F, 27,000 BTU/h, comes from the Senville SENA/24HF/OQ with SENA/24HF/ID, an R-410A pairing rated SEER2 19.2. The highest HSPF2, 13.5, is shared by the MRCOOL O-ES-24-HP-C-230C-O1 and O-HH-24-HP-C-230C-O, each with O-24-HP-WMAH-230C-O, and the Senville SENA-24HF-OG with SENA-24HF-IGG.

42 pairings, sorted by SEER2, highest first.

Outdoor unitBrandSeriesIndoor unitSEER2HSPF2Heat at 47°F BTU/hHeat at 5°F BTU/hKept at 5°F % of 47°FCold climateRefrigerantSeller
SENE-24EL-OHSenvilleSENESENE-24EL-IHH25.011.024,00020,00083%YesR-454BSenville
048-C-TP-23K2V-23S-OUTDellaTP048-C-TP-23K2V-C-IN23.09.525,00018,60074%YesR-454BDella
048-TP-23K2V-23S-OUTDellaTP048-TP-23K2V-23S-IN23.09.525,00018,60074%YesR-454BDella
048-TP-23K2V-23S-OUTDellaTP048-TP-23K2V-C-IN23.09.525,00018,60074%YesR-454BDella
AEPL**MHV22S2431B1AMRCOOLTruInverterAEPL**AWM22E2431B1A23.010.024,00017,50073%YesR-32MRCOOL
YN024GLSI24RPGPioneerDiamante UltraWT024GLSI24HLG23.09.525,00018,60074%YesR-454BPioneer
DIY-24-HP-C-230D25-OMRCOOLDIYDIY-24-HP-WMAH-230D25-O22.79.524,00016,10067%NoR-454BMRCOOL
DIYP-24-HP-C-230DE11-OMRCOOLDIYPDIYP-24-HP-WMAH-230DE13-O22.79.524,00016,10067%NoR-454BMRCOOL
048-C-TPH-24K2V-23S-OUTDellaTPH048-C-TPH-24K2V-C-IN22.510.024,00022,40093%YesR-454BDella
048-TP-23K2V-23S-OUTDellaCC048-CC-24K2V-IN22.510.425,00019,10076%YesR-454BDella
048-TPH-24K2V-23S-OUTDellaTPH048-TPH-24K2V-23S-IN22.510.024,00022,40093%YesR-454BDella
048-TPH-24K2V-23S-OUTDellaTPH048-TPH-24K2V-C-IN22.510.024,00022,40093%YesR-454BDella
YN024GLSI24RPGPioneerDiamante UltraCT024GLSILCFHG22.510.425,00019,10076%YesR-454BPioneer
YN024GLSI25RPHPioneerDiamante HyperformanceWT024GLSI25HLH22.510.024,00022,40093%YesR-454BPioneer
048-MS-24K2VR-22S-M-OUTDellaM048-MS-24K2VR-22S-M-IN22.010.024,00020,80087%YesR-32Della
O-ES-24-HP-C-230BMRCOOLOO-24-HP-WMAH-230B22.010.025,00015,50062%NoR-410AMRCOOL
O-HH-24-HP-C-230AMRCOOLOO-24-HP-WMAH-230B21.511.429,00025,00086%YesR-410AMRCOOL
O-HH-24-HP-C-230BMRCOOLOO-24-HP-WMAH-230B21.511.429,00025,00086%YesR-410AMRCOOL
YN024GMFI20RPDPioneerYNCB024GMFILDFHE21.59.725,00018,50074%YesR-410APioneer
YN024GMFI22RPEPioneerYNCB024GMFILCFHE21.59.725,00018,50074%YesR-410APioneer
YN024GMFI22RPEPioneerYNCB024GMFILDFHE21.59.725,00018,50074%YesR-410APioneer
SENA/24HF/OQSenvilleSENSENA/24HF/IQ21.511.429,00025,00086%YesR-410ASenville
YN024GMFI22RPEPioneerYNUB024GMFILCFHD21.210.324,00018,20076%YesR-410APioneer
O-ES-24-HP-C-230C-O1MRCOOLOO-24-HP-WMAH-230C-O21.013.529,00024,20083%YesR-454BMRCOOL
O-HH-24-HP-C-230C-OMRCOOLO-HHO-24-HP-WMAH-230C-O21.013.529,00024,20083%YesR-454BMRCOOL
YN024GHFI25RPHPioneerWYF HyperformanceWF024GHFI25HLH21.010.024,00018,20076%YesR-410APioneer
YN024GMFI22RPEPioneerYNWS024GMFI22HLE21.09.026,00016,60064%NoR-410APioneer
SENA-24HF-OGSenvilleSENASENA-24HF-IGG21.013.529,00024,20083%YesR-454BSenville
O-HH-24-HP-C-230C-OMRCOOLO-HHCASSETTE24HP-230C-O20.711.625,00023,80095%YesR-454BMRCOOL
SENA-24HF-OGSenvilleSENASENA-24HF-ICG20.711.625,00023,80095%YesR-454BSenville
DIY-24-HP-C-230C25MRCOOLDIYDIY-24-HP-WMAH-230C2520.59.225,00015,50062%NoR-410AMRCOOL
DIY-24-HP-C-230CMRCOOLDIYDIY-24-HP-WMAH-230C2520.59.225,00015,50062%NoR-410AMRCOOL
SENA/24HF/OQSenvilleSENSENA/24HF/ICQ20.511.525,00025,800103%YesR-410ASenville
SENA/24HF/OQSenvilleSENSENA/24HF/IF20.511.025,00025,000100%YesR-410ASenville
048-TP-24K2V-20S-OUTDellaTP048-TP-24K2V-20S-IN20.09.024,00016,00067%NoR-410ADella
SENA/24HF/OQSenvilleSENSENA/24HF/ID19.210.525,00027,000108%YesR-410ASenville
048-TCQ-MODU-1D3DellaTCQnot listed19.010.027,00019,00070%YesR-32Della
O-HH-24-HP-C-230C-OMRCOOLO-HHDUCT-24HP-230B-O19.011.726,00024,00092%YesR-454BMRCOOL
YN024GMFI22RPEPioneerYNRB024GMFILDFHD19.011.225,00020,00080%YesR-410APioneer
SENA-24HF-OGSenvilleSENASENA-24HF-IDG19.011.726,00024,00092%YesR-454BSenville
A-24-HP-C-230D-OMRCOOLAA-24-HP-WMAH-230D-O18.79.324,00017,00071%YesR-454BMRCOOL
SENL-24CD-OLSenvilleSENLSENL-24CD-ILL18.79.324,00017,00071%YesR-454BSenville

Kept at 5°F is calculated by DIY Splits, not certified: the heat output at 5°F divided by the heat output at 47°F, both from the certified data.

More heat at 47°F than the cooling rating

The HSPF2 leaders also put out the most heat at 47°F at this size, 29,000 BTU/h, against 24,000 BTU/h of cooling. The SENE-24EL-OH, by comparison, is certified for 24,000 BTU/h at 47°F. The most heat at 47°F is not the most at 5°F: the HSPF2 leaders put out 24,200 BTU/h at 5°F, while the SENA/24HF/OQ with SENA/24HF/ID, rated 25,000 BTU/h at 47°F, puts out more at 5°F than at 47°F.

MRCOOL DIY and O series at this size

The MRCOOL DIY-24-HP-C-230C25 and DIY-24-HP-C-230C, each with DIY-24-HP-WMAH-230C25, put out 15,500 BTU/h at 5°F, 62% of their 47°F output, the least at this size on both measures, tied with the MRCOOL O-ES-24-HP-C-230B with O-24-HP-WMAH-230B. The DIY-24-HP-C-230D25-O with DIY-24-HP-WMAH-230D25-O keeps 67%. None of these four is listed as cold climate, and each keeps less than the 70% that ENERGY STAR’s cold climate criteria require.

Sources

  1. ENERGY STAR's cold climate criteria include heating capacity at 5°F of at least 70% of the capacity at 47°F. www.energystar.gov

Related

Data: ENERGY STAR certified heat pumps, last checked November 23, 2026