How do the 24,000 BTU mini splits compare?
No 24,000 BTU pairing leads on both cooling and heating. The Senville SENE-24EL-OH with SENE-24EL-IHH has the highest SEER2, 25.0, but puts out 20,000 BTU/h at 5°F, 83% of its 47°F output. The most heat at 5°F, 27,000 BTU/h, comes from the Senville SENA/24HF/OQ with SENA/24HF/ID, an R-410A pairing rated SEER2 19.2. The highest HSPF2, 13.5, is shared by the MRCOOL O-ES-24-HP-C-230C-O1 and O-HH-24-HP-C-230C-O, each with O-24-HP-WMAH-230C-O, and the Senville SENA-24HF-OG with SENA-24HF-IGG.
42 pairings, sorted by SEER2, highest first.
| Outdoor unit | Brand | Series | Indoor unit | SEER2 | HSPF2 | Heat at 47°F BTU/h | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Cold climate | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|---|
| SENE-24EL-OH | Senville | SENE | SENE-24EL-IHH | 25.0 | 11.0 | 24,000 | 20,000 | 83% | Yes | R-454B | Senville |
| 048-C-TP-23K2V-23S-OUT | Della | TP | 048-C-TP-23K2V-C-IN | 23.0 | 9.5 | 25,000 | 18,600 | 74% | Yes | R-454B | Della |
| 048-TP-23K2V-23S-OUT | Della | TP | 048-TP-23K2V-23S-IN | 23.0 | 9.5 | 25,000 | 18,600 | 74% | Yes | R-454B | Della |
| 048-TP-23K2V-23S-OUT | Della | TP | 048-TP-23K2V-C-IN | 23.0 | 9.5 | 25,000 | 18,600 | 74% | Yes | R-454B | Della |
| AEPL**MHV22S2431B1A | MRCOOL | TruInverter | AEPL**AWM22E2431B1A | 23.0 | 10.0 | 24,000 | 17,500 | 73% | Yes | R-32 | MRCOOL |
| YN024GLSI24RPG | Pioneer | Diamante Ultra | WT024GLSI24HLG | 23.0 | 9.5 | 25,000 | 18,600 | 74% | Yes | R-454B | Pioneer |
| DIY-24-HP-C-230D25-O | MRCOOL | DIY | DIY-24-HP-WMAH-230D25-O | 22.7 | 9.5 | 24,000 | 16,100 | 67% | No | R-454B | MRCOOL |
| DIYP-24-HP-C-230DE11-O | MRCOOL | DIYP | DIYP-24-HP-WMAH-230DE13-O | 22.7 | 9.5 | 24,000 | 16,100 | 67% | No | R-454B | MRCOOL |
| 048-C-TPH-24K2V-23S-OUT | Della | TPH | 048-C-TPH-24K2V-C-IN | 22.5 | 10.0 | 24,000 | 22,400 | 93% | Yes | R-454B | Della |
| 048-TP-23K2V-23S-OUT | Della | CC | 048-CC-24K2V-IN | 22.5 | 10.4 | 25,000 | 19,100 | 76% | Yes | R-454B | Della |
| 048-TPH-24K2V-23S-OUT | Della | TPH | 048-TPH-24K2V-23S-IN | 22.5 | 10.0 | 24,000 | 22,400 | 93% | Yes | R-454B | Della |
| 048-TPH-24K2V-23S-OUT | Della | TPH | 048-TPH-24K2V-C-IN | 22.5 | 10.0 | 24,000 | 22,400 | 93% | Yes | R-454B | Della |
| YN024GLSI24RPG | Pioneer | Diamante Ultra | CT024GLSILCFHG | 22.5 | 10.4 | 25,000 | 19,100 | 76% | Yes | R-454B | Pioneer |
| YN024GLSI25RPH | Pioneer | Diamante Hyperformance | WT024GLSI25HLH | 22.5 | 10.0 | 24,000 | 22,400 | 93% | Yes | R-454B | Pioneer |
| 048-MS-24K2VR-22S-M-OUT | Della | M | 048-MS-24K2VR-22S-M-IN | 22.0 | 10.0 | 24,000 | 20,800 | 87% | Yes | R-32 | Della |
| O-ES-24-HP-C-230B | MRCOOL | O | O-24-HP-WMAH-230B | 22.0 | 10.0 | 25,000 | 15,500 | 62% | No | R-410A | MRCOOL |
| O-HH-24-HP-C-230A | MRCOOL | O | O-24-HP-WMAH-230B | 21.5 | 11.4 | 29,000 | 25,000 | 86% | Yes | R-410A | MRCOOL |
| O-HH-24-HP-C-230B | MRCOOL | O | O-24-HP-WMAH-230B | 21.5 | 11.4 | 29,000 | 25,000 | 86% | Yes | R-410A | MRCOOL |
| YN024GMFI20RPD | Pioneer | YN | CB024GMFILDFHE | 21.5 | 9.7 | 25,000 | 18,500 | 74% | Yes | R-410A | Pioneer |
| YN024GMFI22RPE | Pioneer | YN | CB024GMFILCFHE | 21.5 | 9.7 | 25,000 | 18,500 | 74% | Yes | R-410A | Pioneer |
| YN024GMFI22RPE | Pioneer | YN | CB024GMFILDFHE | 21.5 | 9.7 | 25,000 | 18,500 | 74% | Yes | R-410A | Pioneer |
| SENA/24HF/OQ | Senville | SEN | SENA/24HF/IQ | 21.5 | 11.4 | 29,000 | 25,000 | 86% | Yes | R-410A | Senville |
| YN024GMFI22RPE | Pioneer | YN | UB024GMFILCFHD | 21.2 | 10.3 | 24,000 | 18,200 | 76% | Yes | R-410A | Pioneer |
| O-ES-24-HP-C-230C-O1 | MRCOOL | O | O-24-HP-WMAH-230C-O | 21.0 | 13.5 | 29,000 | 24,200 | 83% | Yes | R-454B | MRCOOL |
| O-HH-24-HP-C-230C-O | MRCOOL | O-HH | O-24-HP-WMAH-230C-O | 21.0 | 13.5 | 29,000 | 24,200 | 83% | Yes | R-454B | MRCOOL |
| YN024GHFI25RPH | Pioneer | WYF Hyperformance | WF024GHFI25HLH | 21.0 | 10.0 | 24,000 | 18,200 | 76% | Yes | R-410A | Pioneer |
| YN024GMFI22RPE | Pioneer | YN | WS024GMFI22HLE | 21.0 | 9.0 | 26,000 | 16,600 | 64% | No | R-410A | Pioneer |
| SENA-24HF-OG | Senville | SENA | SENA-24HF-IGG | 21.0 | 13.5 | 29,000 | 24,200 | 83% | Yes | R-454B | Senville |
| O-HH-24-HP-C-230C-O | MRCOOL | O-HH | CASSETTE24HP-230C-O | 20.7 | 11.6 | 25,000 | 23,800 | 95% | Yes | R-454B | MRCOOL |
| SENA-24HF-OG | Senville | SENA | SENA-24HF-ICG | 20.7 | 11.6 | 25,000 | 23,800 | 95% | Yes | R-454B | Senville |
| DIY-24-HP-C-230C25 | MRCOOL | DIY | DIY-24-HP-WMAH-230C25 | 20.5 | 9.2 | 25,000 | 15,500 | 62% | No | R-410A | MRCOOL |
| DIY-24-HP-C-230C | MRCOOL | DIY | DIY-24-HP-WMAH-230C25 | 20.5 | 9.2 | 25,000 | 15,500 | 62% | No | R-410A | MRCOOL |
| SENA/24HF/OQ | Senville | SEN | SENA/24HF/ICQ | 20.5 | 11.5 | 25,000 | 25,800 | 103% | Yes | R-410A | Senville |
| SENA/24HF/OQ | Senville | SEN | SENA/24HF/IF | 20.5 | 11.0 | 25,000 | 25,000 | 100% | Yes | R-410A | Senville |
| 048-TP-24K2V-20S-OUT | Della | TP | 048-TP-24K2V-20S-IN | 20.0 | 9.0 | 24,000 | 16,000 | 67% | No | R-410A | Della |
| SENA/24HF/OQ | Senville | SEN | SENA/24HF/ID | 19.2 | 10.5 | 25,000 | 27,000 | 108% | Yes | R-410A | Senville |
| 048-TCQ-MODU-1D3 | Della | TCQ | not listed | 19.0 | 10.0 | 27,000 | 19,000 | 70% | Yes | R-32 | Della |
| O-HH-24-HP-C-230C-O | MRCOOL | O-HH | DUCT-24HP-230B-O | 19.0 | 11.7 | 26,000 | 24,000 | 92% | Yes | R-454B | MRCOOL |
| YN024GMFI22RPE | Pioneer | YN | RB024GMFILDFHD | 19.0 | 11.2 | 25,000 | 20,000 | 80% | Yes | R-410A | Pioneer |
| SENA-24HF-OG | Senville | SENA | SENA-24HF-IDG | 19.0 | 11.7 | 26,000 | 24,000 | 92% | Yes | R-454B | Senville |
| A-24-HP-C-230D-O | MRCOOL | A | A-24-HP-WMAH-230D-O | 18.7 | 9.3 | 24,000 | 17,000 | 71% | Yes | R-454B | MRCOOL |
| SENL-24CD-OL | Senville | SENL | SENL-24CD-ILL | 18.7 | 9.3 | 24,000 | 17,000 | 71% | Yes | R-454B | Senville |
Kept at 5°F is calculated by DIY Splits, not certified: the heat output at 5°F divided by the heat output at 47°F, both from the certified data.
More heat at 47°F than the cooling rating
The HSPF2 leaders also put out the most heat at 47°F at this size, 29,000 BTU/h, against 24,000 BTU/h of cooling. The SENE-24EL-OH, by comparison, is certified for 24,000 BTU/h at 47°F. The most heat at 47°F is not the most at 5°F: the HSPF2 leaders put out 24,200 BTU/h at 5°F, while the SENA/24HF/OQ with SENA/24HF/ID, rated 25,000 BTU/h at 47°F, puts out more at 5°F than at 47°F.
MRCOOL DIY and O series at this size
The MRCOOL DIY-24-HP-C-230C25 and DIY-24-HP-C-230C, each with DIY-24-HP-WMAH-230C25, put out 15,500 BTU/h at 5°F, 62% of their 47°F output, the least at this size on both measures, tied with the MRCOOL O-ES-24-HP-C-230B with O-24-HP-WMAH-230B. The DIY-24-HP-C-230D25-O with DIY-24-HP-WMAH-230D25-O keeps 67%. None of these four is listed as cold climate, and each keeps less than the 70% that ENERGY STAR’s cold climate criteria require.
Sources
- ENERGY STAR's cold climate criteria include heating capacity at 5°F of at least 70% of the capacity at 47°F. www.energystar.gov
Related
- How do the 18,000 BTU mini splits compare?
- Which mini splits put out the most heat at 5°F, and which keep the most of their 47°F output?
- Heating output by outdoor temperature
- Finder: every unit in one table
- Does installing a mini split yourself void the warranty?
Data: ENERGY STAR certified heat pumps, last checked November 23, 2026