Which mini splits put out the most heat at 5°F, and which keep the most of their 47°F output?
On heat output at 5°F, a large unit leads: the Senville SENA-55HF-MOA, an outdoor unit listed without an indoor unit, is certified for 48,000 BTU/h at 5°F, the most of any pairing from the four brands, which is 87% of its output at 47°F. On the share of 47°F output kept at 5°F, smaller units lead: the Senville SENE-09EL-OH, SENE-12EL-OH and SENE-18EL-OH, each with its SENE indoor unit, put out 113% of their 47°F output at 5°F. ENERGY STAR's cold climate criteria require at least 70%.
Pairings listed as ENERGY STAR cold climate. 20 pairings with heat output at 5°F 30,000 or higher, sorted by heat output at 5°F, highest first.
| Outdoor unit | Brand | Series | Indoor unit | Cooling BTU/h | Heat at 47°F BTU/h | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | COP at 5°F | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|---|
| SENA-55HF-MOA | Senville | SENA | not listed | 53,000 | 55,000 | 48,000 | 87% | 2.10 | R-454B | Senville |
| SENA-48HF-MOA | Senville | SENA | not listed | 47,000 | 49,000 | 47,000 | 96% | 2.00 | R-454B | Senville |
| DIY-MULTI6-55HP230D-O | MRCOOL | DIY | not listed | 47,000 | 55,000 | 46,000 | 84% | 2.00 | R-454B | MRCOOL |
| SENA-48HF-MOB | Senville | SENA | not listed | 48,000 | 49,000 | 45,000 | 92% | 2.00 | R-410A | Senville |
| 048-TLP-MODU-1D6 | Della | TLP | not listed | 55,000 | 55,000 | 42,000 | 76% | 2.00 | R-454B | Della |
| 048-TPH-MODU-1D6 | Della | TPH | not listed | 48,000 | 48,000 | 41,000 | 85% | 1.75 | R-454B | Della |
| YN060GLSI24M6G | Pioneer | Quantum Ultra Multi | not listed | 55,000 | 55,000 | 41,000 | 75% | 1.75 | R-454B | Pioneer |
| YN048GMSI20RUG | Pioneer | YN | CB048GMSILDFHG | 48,000 | 50,000 | 40,500 | 81% | 2.11 | R-454B | Pioneer |
| YN048GMSI20RUG | Pioneer | YN | UB048GMSILDFHG | 48,000 | 50,000 | 38,500 | 77% | 1.95 | R-454B | Pioneer |
| YN048GMSI20RUG | Pioneer | YN | RB048GMSILDFHG | 48,000 | 50,000 | 38,000 | 76% | 2.00 | R-454B | Pioneer |
| DIY-MULTI6-48HP230D-O | MRCOOL | DIY | not listed | 43,000 | 48,000 | 37,000 | 77% | 2.00 | R-454B | MRCOOL |
| SENA-36HF-MOB | Senville | SENA | not listed | 36,000 | 36,000 | 37,000 | 103% | 2.00 | R-410A | Senville |
| MULTI6-48HP230C-O | MRCOOL | MULTI | not listed | 47,000 | 48,000 | 36,000 | 75% | 2.00 | R-454B | MRCOOL |
| SENA-36HF-MOA | Senville | SENA | not listed | 36,000 | 36,000 | 36,000 | 100% | 2.00 | R-454B | Senville |
| YN048GMFI18RUE | Pioneer | YN | UB048GMFILCFHD | 48,000 | 50,000 | 35,000 | 70% | 1.85 | R-410A | Pioneer |
| SENA-33HF-OG | Senville | SENA | SENA-33HF-IGG | 33,000 | 36,000 | 35,000 | 97% | 1.98 | R-454B | Senville |
| SENA-33HF-OQ | Senville | SEN | SENA-33HF-IQ | 33,000 | 35,000 | 34,600 | 99% | 1.80 | R-410A | Senville |
| 048-TLP-MODU-1D5 | Della | MODU | not listed | 41,000 | 42,000 | 33,000 | 79% | 1.90 | R-454B | Della |
| 048-TPH-MODU-1D5 | Della | TPH | not listed | 36,000 | 36,000 | 33,000 | 92% | 1.90 | R-454B | Della |
| YN050GLSI24M5G | Pioneer | Quantum Ultra Multi | not listed | 42,000 | 42,000 | 30,000 | 71% | 2.00 | R-454B | Pioneer |
Kept at 5°F is calculated by DIY Splits, not certified: the heat output at 5°F divided by the heat output at 47°F, both from the certified data.
The table lists the cold climate pairings with the most heat at 5°F. The SENE pairings that lead on share kept put out less heat than the table’s cut and are not in it; the heating output by temperature tool shows the share kept by every pairing.
Two different measures
Heat output at 5°F is how much heat a pairing delivers at that temperature. The share kept is that output divided by the pairing’s output at 47°F. A large unit can lead the first and still lose more of its heat; a small unit can lead the second and still deliver less. The SENE-09EL-OH with SENE-09EL-IHH is certified for 13,500 BTU/h at 5°F and 12,000 BTU/h at 47°F, so its share is 113%.
Among the pairings in the table, the Senville SENA-36HF-MOB keeps the largest share: 37,000 BTU/h at 5°F, 103% of its 47°F output.
Most heat at 5°F in each size up to 24,000 BTU
Across all pairings from the four brands in each size up to 24,000 BTU:
- 9,000 BTU: 13,500 BTU/h, Senville SENE-09EL-OH with SENE-09EL-IHH
- 12,000 BTU: 13,500 BTU/h, Senville SENE-12EL-OH with SENE-12EL-IHH
- 18,000 BTU: 22,600 BTU/h, Senville SENE-18EL-OH with SENE-18EL-IHH
- 24,000 BTU: 27,000 BTU/h, Senville SENA/24HF/OQ with SENA/24HF/ID
What the cold climate listing requires
ENERGY STAR lists a heat pump as cold climate when its COP at 5°F is at least 1.75, its heating capacity at 5°F is at least 70% of its capacity at 47°F, its SEER2 is at least 15.2 and, for a non-ducted split system, its HSPF2 is at least 8.5. Its performance must also be confirmed by a controls verification procedure. COP is the heating rate divided by the electrical power used, so it measures efficiency at 5°F, not output.
A pairing that is not listed as cold climate still has certified 5°F figures. The MRCOOL DIY-12-HP-C-115C25 with DIY-12-HP-WMAH-115C25 keeps 53% of its 47°F output at 5°F.
Between the certified points
The data has certified heating figures at 5, 17 and 47°F, and none below 5°F. The same tool estimates each pairing’s output at temperatures in between.
Sources
- ENERGY STAR's cold climate criteria for a heat pump are a COP at 5°F of at least 1.75, heating capacity at 5°F of at least 70% of the capacity at 47°F, SEER2 of at least 15.2 and, for non-ducted split systems, HSPF2 of at least 8.5, with performance confirmed by a controls verification procedure. www.energystar.gov
- ENERGY STAR defines COP as the heating rate divided by the electrical power used, with no units. www.energystar.gov
Related
- Heating output by outdoor temperature
- Finder: every unit in one table
- How do the 24,000 BTU mini splits compare?
- Is there still a federal tax credit for a mini split?
Data: ENERGY STAR certified heat pumps, last checked November 23, 2026