The four brands differ most on installing the unit yourself. MRCOOL says its DIY system is designed for homeowner installation and keeps its full warranty whoever installs it; Senville's warranty registration page says DIY installation will void the warranty; Pioneer's help center says refrigerant lines and vacuuming must be done by qualified installers; Della's MS-JA series manual says mini splits need vacuum pumping. On the certified figures at 12,000 BTU, the Senville SENE-12EL-OH with SENE-12EL-IHH has the highest SEER2, 29.4. The highest from MRCOOL at that size is 25.5, and from Della and Pioneer 25.0.
12,000 BTU pairings from the four brands. 22 pairings with SEER2 24.0 or higher, sorted by SEER2, highest first.
| Outdoor unit | Brand | Series | Indoor unit | SEER2 | HSPF2 | Heat at 5°F BTU/h | Kept at 5°F % of 47°F | Refrigerant | Seller |
|---|---|---|---|---|---|---|---|---|---|
| SENE-12EL-OH | Senville | SENE | SENE-12EL-IHH | 29.4 | 12.7 | 13,500 | 113% | R-454B | Senville |
| O-HH-12-HP-C-230A | MRCOOL | O | O-12-HP-WMAH-230B | 25.5 | 10.4 | 12,000 | 100% | R-410A | MRCOOL |
| O-HH-12-HP-C-230B | MRCOOL | O | O-12-HP-WMAH-230B | 25.5 | 10.4 | 12,000 | 100% | R-410A | MRCOOL |
| SENA/12HF/OQ | Senville | SEN | SENA/12HF/IQ | 25.5 | 10.4 | 12,000 | 100% | R-410A | Senville |
| O-ES-12-HP-C-230C-O1 | MRCOOL | O-ES | O-12-HP-WMAH-230C-O | 25.4 | 10.5 | 11,500 | 96% | R-454B | MRCOOL |
| O-HH-12-HP-C-230C-O | MRCOOL | O-HH | O-12-HP-WMAH-230C-O | 25.4 | 10.5 | 11,500 | 96% | R-454B | MRCOOL |
| SENA-12HF-OG | Senville | SENA | SENA-12HF-IGG | 25.4 | 10.5 | 11,500 | 96% | R-454B | Senville |
| 048-C-TPH-12K2V-25S-OUT | Della | TPH | 048-C-TPH-12K2V-C-IN | 25.0 | 10.5 | 12,000 | 100% | R-454B | Della |
| 048-TPH-12K2V-25S-OUT | Della | TPH | 048-TPH-12K2V-25S-IN | 25.0 | 10.5 | 12,000 | 100% | R-454B | Della |
| 048-TPH-12K2V-25S-OUT | Della | TPH | 048-TPH-12K2V-C-IN | 25.0 | 10.5 | 12,000 | 100% | R-454B | Della |
| YN012GLSI25RPH | Pioneer | Diamante Hyperformance | WT012GLSI25HLH | 25.0 | 10.5 | 12,000 | 100% | R-454B | Pioneer |
| SENA-12HF-OG | Senville | SENA | SENA-12HF-IFG | 25.0 | 10.5 | 11,300 | 94% | R-454B | Senville |
| O-ES-12-HP-C-230B | MRCOOL | O | O-12-HP-WMAH-230B | 24.6 | 10.7 | 8,000 | 67% | R-410A | MRCOOL |
| YN012GMSI24RPG | Pioneer | YN | FB012GMSILDFHG | 24.6 | 11.0 | 8,900 | 74% | R-454B | Pioneer |
| SENA/12HF/OQ | Senville | SEN | SENA-12HF-IFU | 24.2 | 10.7 | 11,900 | 99% | R-410A | Senville |
| 048-C-TP-12K2V-24S-OUT | Della | TP | 048-C-TP-12K2V-C-IN | 24.0 | 10.0 | 9,100 | 72% | R-454B | Della |
| 048-TP-12K2V-24S-OUT | Della | TP | 048-TP-12K2V-24S-IN | 24.0 | 10.0 | 9,100 | 72% | R-454B | Della |
| 048-TP-12K2V-24S-OUT | Della | TP | 048-TP-12K2V-C-IN | 24.0 | 10.0 | 9,100 | 72% | R-454B | Della |
| AEPL**MHV23S1231B1A | MRCOOL | TruInverter | AEPL**AWM23E1231B1A | 24.0 | 10.0 | 10,000 | 83% | R-32 | MRCOOL |
| AEPL**MHV23S1232B1A | MRCOOL | TruInverter | AEPL**AWM23E1232B1A | 24.0 | 10.0 | 10,000 | 83% | R-32 | MRCOOL |
| YN012GLSI24RPG | Pioneer | Diamante Ultra | WT012GLSI24HLG | 24.0 | 10.0 | 9,100 | 72% | R-454B | Pioneer |
| YN012GLUI25RPQ | Pioneer | Diamante Fresh | WT012GLUI25FVQ | 24.0 | 9.5 | 10,100 | 77% | R-32 | Pioneer |
Kept at 5°F is calculated by DIY Splits, not certified: the heat output at 5°F divided by the heat output at 47°F, both from the certified data.
What each maker says about installation
MRCOOL’s Quick Connect line sets ship pre-charged and sealed, and joining the couplers opens the valves without letting outside air in, so there is no vacuum pump step. MRCOOL says cutting the lines vents the refrigerant and voids the warranty. Its warranty document for 5th Generation DIY systems gives 5 years on parts and 7 years on the compressor, with no registration.
Senville’s warranty registration page says pressure testing and evacuation of the line set must be done by a licensed HVAC professional for the warranty to be valid, and that labor is not covered.
Pioneer’s help center says owners may help mount the indoor and outdoor units, and that the warranty requires correct installation per the manual.
Della’s MS-JA series manual says to hire a licensed professional if you are not familiar with electrical wiring and HVAC systems, and excludes damage from faulty installation from its warranty.
Each statement is reported from the document named and is not extended here to the brand’s other models. The installation and warranty page gives them in more detail.
Certified figures at 12,000 BTU
The Senville SENE-12EL-OH with SENE-12EL-IHH also leads the table on HSPF2, at 12.7, and on heat output at 5°F, at 13,500 BTU/h. MRCOOL’s DIY series pairings at this size are rated from 22.2 to 23.5 SEER2, below the table’s cut; the installation and warranty page lists them.
Matching figures across brands
Pairings from different brands often carry the same certified figures. The Della 048-TPH-12K2V-25S-OUT with 048-TPH-12K2V-25S-IN and the Pioneer YN012GLSI25RPH with WT012GLSI25HLH both have SEER2 25.0, HSPF2 10.5 and 12,000 BTU/h at 5°F. The MRCOOL O-HH-12-HP-C-230C-O with O-12-HP-WMAH-230C-O and the Senville SENA-12HF-OG with SENA-12HF-IGG both have SEER2 25.4, HSPF2 10.5 and 11,500 BTU/h at 5°F. The same pairs of brands match at other sizes: Della with Pioneer, and MRCOOL with Senville. The certified data does not say why.
Sources
- MRCOOL says its DIY system is designed for do-it-yourself installation, that its Quick Connect line sets ship pre-charged and sealed so no vacuum pump step is needed, that cutting the lines voids the warranty, and that the warranty stays fully intact whether a professional or the homeowner installs the system. www.mrcool.com
- MRCOOL's 5th Generation DIY warranty document gives 5 years on parts and 7 years on the compressor with no registration, for systems installed per the instructions and local law, and excludes labor, refrigerant costs and faulty installation. doxrepo.mrcool.com
- Senville's warranty registration page says line-set pressure testing and evacuation must be done by a licensed HVAC professional for the warranty to be valid, that DIY installation will void the warranty, and that labor is not covered. senville.com
- Pioneer's help center says refrigerant lines, vacuuming and recharging must be done by qualified installers, that owners may help mount the indoor and outdoor units, and that the warranty requires correct installation per the manual. www.pioneerminisplit.com
- Della's MS-JA series manual says mini splits need vacuum pumping, says to hire a licensed professional if you are not familiar with electrical wiring and HVAC systems, and excludes labor and damage from faulty installation from the warranty. dellahome.com